SYNCO CHEMICAL CORP -- SUPER LUBE AEROSOL WITH HEPTANE -- 9150-00N059631
===================== Product Identification =====================
Product ID:SUPER LUBE AEROSOL WITH HEPTANE
MSDS Date:04/08/1994
FSC:9150
NIIN:00N059631
=== Responsible Party ===
Company Name:SYNCO CHEMICAL CORP
Address:24 DAVINCI DR
City:BOHEMIA
State:NY
ZIP:11716
Country:US
Info Phone Num:516-567-5300
Emergency Phone Num:516-567-5300
CAGE:4Y181
=== Contractor Identification ===
Company Name:SYNCO CHEMICAL CORP
Address:24 DAVINCI DR
Box:City:BOHEMIA
State:NY
ZIP:11716-2601
Country:US
Phone:516-567-5301
CAGE:4Y181
============= Composition/Information on Ingredients =============
Ingred Name:1-DECENE, HOMOPOLYMER, HYDROGENATED; (SYNTHETIC HYDROCARBON
POLYALPHAOLEFIN BASE FLUID)
CAS:68037-01-4
Fraction by Wt: 31%
OSHA PEL:5 MG/M3 (MFR)
ACGIH TLV:N/K
Ingred Name:SILANE, DICHLORODIMETHYL-, REACTION PRODUCTS WITH SILICA;
(FUMED SILICA)
CAS:68611-44-9
Fraction by Wt: 3%
OSHA PEL:10 MG/M3 (MFR)
ACGIH TLV:N/K
Ingred Name:ETHYLENE, TETRAFLUORO-, POLYMER; (POLYTETRAFLUOROETHYLENE)
CAS:116-14-3
RTECS #:KX4025000
Fraction by Wt: 2%
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:HEPTANE
CAS:142-82-5
RTECS #:MI7700000
Fraction by Wt: 61%
OSHA PEL:500 PPM
ACGIH TLV:400 PPM
Ingred Name:CARBON DIOXIDE
CAS:124-38-9
RTECS #:FF6400000
Fraction by Wt: 3%
OSHA PEL:5000 PPM
ACGIH TLV:5000 PPM
Ingred Name:RESP PROT:APPROVED SCBA IS REQUIRED FOR VAPOR
CONCENTRATIONS ABOVE PEL/TLV LIMITS.
RTECS #:9999999ZZ
Ingred Name:VENT:HAZARDOUS INGREDIENT BELOW ACCEPTABLE LIMIT AND LEL
BELOW STATED LIMIT.
RTECS #:9999999ZZ
Ingred Name:EYE PROT:AND FULL LENGTH FACE SHIELD .
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:RESP IRRIT, HDCH, NAUS,
FATG, DROW, IMPAIRED COORD. SKIN:POSS IRRIT. CONT MAY DRY; PRLNGD
CONT MAY CAUSE MOD IRRIT. EYES:LIQ/VAP CAN CAUSE MOD TO SEV IRRIT.
SKIN ABSORP:NOT EASILY ABSORBED . SOLV ACTION CAN DRY & DEFAT
CAUSING SKIN TO CRACK, LEADING TO DERM. INGEST:NOT LIKELY RTE OF
EXPOS. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS:IF SWALLOWED, DO NOT INDUCE VOMIT.
SEEK IMMED MED ADVICE &/OR ATTN. CHRONIC:NONE KNOWN.
Medical Cond Aggravated by Exposure:NONE KNOWN.
======================= First Aid Measures =======================
First Aid:INHAL:REMOVE TO FRESH AIR. ADMIN OXYG IF NEEDED. APPLY ARTF
RESP IF BRTHG HAS STOPPED. GET MED ATTN. SKIN:WIPE OFF W/TOWEL.
WASH W/SOAP & WATER. GET MED ATTN IF IRRIT PERSISTS. EYES:WASH
IMMED W/LG VO LS OF FRESH WATER FOR AT LEAST 15 MINUTES. GET
MEDICAL ATTENTION. INGESTION:DO NOT INDUCE VOMITING. SEEK IMMEDIATE
MEDICAL ADVICE AND/OR ATTENTION.
===================== Fire Fighting Measures =====================
Extinguishing Media:FOAM, ALCOHOL FOAM, CO*2, DRY CHEMICAL, WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
WATER SPRAY MAY BE INEFTIVE. WATER MAY BE USED TO COOL CNTNRS TO
PVNT PRESS BUILD-UP & EXPLO WHEN (SUP DAT)
Unusual Fire/Explosion Hazard:CLSD CNTNRS MAY EXPLODE FROM INTERNAL
PRESS BUILD-UP WHEN EXPOSED TO EXTREME HEAT & DISCHARGE CONTENTS.
VAP ACCUM CAN FLASH/EXPLODE IF IGNITED. OVEREXP (SUPDAT)
================== Accidental Release Measures ==================
Spill Release Procedures:AVOID BREATHING VAPORS. VENTILATE AREA. REMOVE
ALL SOURCES OF IGNITION. CLEAN UP AREA WITH ABSORBENT MATERIAL AND
PLACE IN CLOSED CONTAINERS FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE & USE IN COOL, DRY, WELL-VENT
AREAS. DO NOT STORE >120F. DO NOT PUNCTURE/INCIN (BURN) CANS.
Other Precautions:DO NOT STICK PIN, NAIL/ANY OTHER SHARP OBJECT INTO
OPENING ON TOP OF CAN. DO NOT SPRAY INTO EYES. DO NOT TAKE
INTERNALLY. SEE PROD LBL FOR ADDNL INFO. SM PRESSURIZED CNTNRS OF
FLAM PRODS MAY BE STORED IN AREAS SUITABLE FOR ORDINARY (SUPDAT)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE UNDER NORMAL USE. AVOID BRTHG VAPS. IN
RESTRICTED AREAS, USE NIOSH/MSHA APPRVD CHEM/MECH FILTERS DESIGNED
TO REMOVE COMBINATION OF PARTICLES & VAPS. IN CONFINED AREAS, USE
NIOSH/MSHA APPRVD AIR L INE TYPE RESP/HOOD. NIOSH/MSHA (ING 6)
Ventilation:SUFFICIENT TO PVNT INHAL OF SOLV VAPS. GEN DILUTION &/OR
LOC EXHST VENT IN VOL/PATTERN TO KEEP PEL/TLV OF MOST (ING 7)
Protective Gloves:SOLV RESIST REQ FOR PRLNGD/RPTD CONT.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(ING 8)
Other Protective Equipment:EYE WASHES AND SAFETY SHOWERS IN THE WORK
PLACE ARE RECOMMENDED MEETING ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC:EXPOSED TO EXTREME HEAT. IF WATER IS USED, FOG NOZZS
PREF. EXPLO HAZS:TO DECOMP PRODS MAY CAUSE HLTH HAZ. SYMPS MAY NOT
BE READILY APPARENT. OBTAIN MED ATTN. OTHER PREC:COMBUSTS W/RESP
ECT TO CONSTRUCTION, DRAINAGE, CTL OF IGNIT SOURCES, & VENT EXCEPT
THAT THEY SHOULD NOT BE STORED IN BASEMENTS.
================== Physical/Chemical Properties ==================
Vapor Density:HVR/AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:NIL
Appearance and Odor:AEROSOL PRODUCT
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:APPLICATION TO HOT SURFACES. STORAGE ABOVE
120F. EXPOSURE TO OPEN FLAME.
Hazardous Decomposition Products:MAY PRODUCE FUMES WHEN HEATED TO
DECOMPOSITION. FUMES MAY CONTAIN CARBON MONOXIDE.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS. BEFORE ATTEMPTING CLEAN UP, REFER TO OTHER
SECTIONS OF THIS MSDS FOR HAZARD CAUTION INFORMATION.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.